When to Use E100-VR1™ Clear UV Resistant Epoxy Instead of a Standard Clear Epoxy on Elite Crete Systems Interior Floors
What it is. E100-VR1™ Clear UV Resistant Epoxy is Elite Crete Systems' 100% solids, two-component, water-clear, low-viscosity epoxy formulated for improved resistance to incidental interior UV exposure. TD.473 describes it as a high-gloss coating for protective base or top coats, REFLECTOR™ Enhancer floors, HERMETIC™ color quartz and flake broadcasts, and HERMETIC™ Stout and Paramount floors when UV resistance and hardness matter indoors.
How it differs from a standard clear. Standard clear epoxies (such as E100-PT1™) can degrade under prolonged UV. PI.222 lists improved UV resistance as a primary advantage of E100-VR1™, along with zero VOC, self-leveling with auto air release, antimicrobial and anti-static notes, and field pigmentation with special pigments. Use it when the interior floor will see daylight through windows or skylights and the clear coat must stay clearer longer.
Mixing and cure from TD.473. Mix ratio is 2 parts A to 1 part B by volume. At the TD.473 cure schedule (75°F / 24°C): viscosity Part A / B / mixed about 625 / 175 / 450 cps at 73°F; pot life about 20 minutes; tack free 7 to 8 hours; full traffic +24 hours. Published compressive strength is 11,900 psi (ASTM D695); Shore D hardness 76 (ASTM D2240); VOC 0.00 lb/gal.
Where it sits in a system. PI.222 lists it as base coat (when a vapor barrier epoxy is not required), pigmented coat with special powdered pigment, slurry or trowel binder in Paramount builds, cove primer/binder/clear, general interior concrete sealing, protective sealer for interior polished concrete, and clear coat over interior cementitious overlays.
Limits. Not for exterior concrete. May need a vapor barrier epoxy first when moisture or vapor emission is a concern (see PI.551). Not recommended for continuous water submersion. Store 65°F–85°F; do not freeze; shelf life one year unopened. Opened containers need a nitrogen blanket and airtight reseal. Precondition cold kits to about 70°F before mixing (same cold-epoxy guidance as other E100 clears).
Where to find the numbers. Always work from the current TD.473 and PI.222 at https://www.elitecrete.com/documents-technical-data/. Coverage varies by system — contact an Elite Crete Systems technical office for the build you are installing.