Elite Crete Systems E100 Series clear epoxies, such as E100-PT1™ Clear Epoxy and E100-VR1™ Clear UV Resistant Epoxy, are 100% solids, two-component coatings. Because there is no solvent or water in them, their temperature has a big effect on how they behave in the bucket and on the floor.
What cold does to epoxy. When 100% solids epoxy resins sit in cold temperatures for long periods, they thicken, may crystallize, and become harder to flow or spread. A cold kit is harder to mix completely and harder to roll or squeegee to an even film, and that raises the risk of an uneven finish or a poorly mixed batch.
Precondition before you mix. The Elite Crete Systems product information sheet tells installers to keep the material at about 70°F (21°C) before mixing to improve flow. Plan ahead: bring kits into a heated space well before the job, not the morning of.
If the resin has crystallized. Crystallized epoxy can be reconstituted by holding it at 90°F (32°C) for 12 hours and then remixing it. Do not use a crystallized kit as-is.
Storage. Store unopened containers in temperature-controlled areas above 45°F (7.2°C); under those conditions the published shelf life is one year. Rotate stock, because formula improvements may be made over time. Opened containers need a nitrogen blanket and must be resealed airtight.
Related points from the same sheets. These clear epoxies are interior products and are not for exterior concrete. Some installations need a vapor barrier epoxy first when moisture or vapor emission is a concern (see PI.551, Resinous Flooring Guidelines). Ambient and slab temperature also govern cure time after the coating goes down, so a cold building slows the return to service.
Where to find the numbers. Always work from the current product information sheet (PI), technical data sheet (TD), and safety data sheet (SDS) for the exact product: https://www.elitecrete.com/documents-technical-data/. For a cold-weather job, contact an Elite Crete Systems technical office before you start.